Pelican TH-50VX100U Flat Panel Television User Manual


 
SERIAL
6789
13452
11
Connections
SERIAL Terminals connection
Notes:
Use the RS-232C straight cable to connect the computer
to the Plasma Display.
The computer shown is for example purposes only.
Additional equipment and cables shown are not supplied
with this set.
The SERIAL terminal conforms to the RS-232C interface
specification, so that the Plasma Display can be controlled
by a computer which is connected to this terminal.
The computer will require software which allows the
sending and receiving of control data which satisfies
the conditions given below. Use a computer application
such as programming language software. Refer to the
documentation for the computer application for details.
The SERIAL terminal is used when the Plasma Display is controlled by a computer.
Basic format for control data
The transmission of control data from the computer starts with
a STX signal, followed by the command, the parameters, and
lastly an ETX signal in that order. If there are no parameters,
then the parameter signal does not need to be sent.
Start
(02h)
3-character
command (3 bytes)
Colon Parameter(s)
(1 - 5 bytes)
End
(03h)
STX C1 C2 C3 P1 P2 P3 P4
: P5 ETX
Notes:
If multiple commands are transmitted, be sure to wait for
the response for the first command to come from this unit
before sending the next command.
If an incorrect command is sent by mistake, this unit will
send an “ER401” command back to the computer.
SL1A, SL1B, SL2A and SL2B of Command IMS are
available only when a dual input terminal board is attached.
Pin layout for SERIAL Terminal
COMPUTER
RS-232C Straight cable
D-sub 9p
Command Parameter Control details
PON None Power ON
POF None Power OFF
AVL ** Volume 00 - 63
IMS None
SL1
SL2
SL3
PC1
SL1A
SL1B
SL2A
SL2B
Input select (toggle)
Slot1 input
Slot2 input
Slot3 input
PC input
Slot1 input (INPUT1A)
Slot1 input (INPUT1B)
Slot2 input (INPUT2A)
Slot2 input (INPUT2B)
DAM None
ZOOM
FULL
JUST
NORM
SJST
SNOM
SFUL
Screen mode select (toggle)
ZOOM
FULL
JUST
4:3
JUST
4:3
H-FILL
With the power off, this display responds to PON
command only.
Command
Signal level RS-232C compliant
Synchronization method Asynchronous
Baud rate 9600 bps
Parity None
Character length 8 bits
Stop bit 1 bit
Flow control -
Signal names for D-sub 9P connector
Pin No. Details
2
R X D
3
T X D
5
GND
4
6
Non use
7
8
(Shorted in this set)
1
9
NC
These signal names are those of computer specifications.
Communication parameters
(Male)
(Female)