Perle Systems CM-10GT-SFP TV Converter Box User Manual


 
Perle C/CM-10GT Media Modules Installation Guide
7
Sequence of Events
1. The Local C/CM-10GT media converter module sends the
Remote C/CM-10GT media converter module a signal to go
into test mode.
2. The Remote C/CM-10GT media converter module turns on
test mode.
3. Built In Link Test data is sent from the Local C/CM-10GT
media converter module to the Remote C/CM-10GT media
converter module.
4. The Remote C/CM-10GT media converter module analyses
the received test data and sends its own test data plus a
diagnostic code back to the Local C/CM media converter
module.
5. If the PWR LED on the Local C/CM media converter module
blinks red, this connection may require further testing. The
PWR LED should flash green to indicate that there have been
no errors in the last second.
6. The Built in Link Test continues to run until Switch 1 on the
Local C/CM-10GT media converter module is set to Data
mode.
Fiber Fault Alert (Switch 3 – Data Mode)
Switch Position Mode
Up (default) Enabled
Down Disabled
Enabled: If the media converter module detects a loss of signal on
the fiber port, the media converter module notifies the link partner
on that same port that an error condition exists by bringing down
the link.
Disabled: The media converter module will not monitor for fiber
fault.