This table shows the times for maintenance/inspection of each component. Use the table as reference, since
the maintenance/inspection times vary depending on the environment where the VCR is used and the way it
is used. If the components indicated C/R do not function normally after cleaning, replace them.
Please contact the dealer for detail information.
Maintenance Table
Component and point 1000h 2000h 3000h 4000h 5000h
Cylinder motor assembly C/R R C/R R C/R
A/C head assembly C C/R C R C
FE head C C C R C
S guide roller C C C/R C C
T guide roller C C C/R C C
Tension band brake R R
Tension arm C C C C C
S reel table C C
T reel table C C
PR arm C R C R C
Timing belt C C
Capstan motor C R C R C
Loading motor assembly R
Mechanism state switch (R)
Idler gear 1 R R
Idler gear 2 R R
FR gear RR
JOG Gear C C/R C C/R C
Supply slant pole C C C C C
Take-up slant pole C C C C C
Tape guides C C C C C
Tape guide line on lower cylinder C C C C C
Tension band R R R
FS brake C C/R C C/R C
Pulley assembly R R
HC arm (R)
Shaft and bearing of S reel table S S
Shaft and bearing of T reel table S S
Shaft and bearing of idler gear 1 S S
Shaft and bearing of idler gear 2 S S
Shaft of pulley assembly S S
Shaft of torque change gear and FR drive gear S S
Shaft of PR arm M M
G base assembly moving portions in chassis M
Contact surface between cylinder base and G base
assembly during loading
M
R: Component replacement
C: Cleaning
S: Oil (Sonic Slidas oil) refilling
M: Grease (Molicoat) refilling
MAINTENANCE/INSPECTION SCHEDULES OF MECHANICAL COMPONENTS