6.1
RS-232 Connection
and Port Configuration
To interface the Crystal Series LCD with a home theater automation/control system or a
PC running terminal emulation software, connect it to your control system or PC as shown
in
Figure 3-10. (Use a straight-through cable.)
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop
bit and no flow control. Set the baud rate to match that of the Crystal Series LCD RS-232
port. To check the baud rate setting, select
Baud Rate from the ISF Calibration menu (refer
to page 41).
6.2
Serial Command
Syntax
Commands are in ASCII format and are not case-sensitive.
A carriage return is not required after a command.
When you send a valid command, the Crystal Series LCD executes it and
acknowledges it with a right-bracket character (]) followed by the four-digit numeric
code you sent; for example, ]0002.
When you send an invalid command (one followed by values outside the valid range for
that command), the Crystal Series LCD ignores it and returns >MAX or <MIN instead of
the four-digit code.
When you send an unrecognized/misspelled command, the Crystal Series LCD ignores
it and returns -N/A instead of the four-digit code.
Table 6-1 lists the RS-232 command set.
6. Serial Communications
Table 6-1. Serial Commands
Command Description
[ S3A 0###
Set audio volume to ### ( = 000-100)
Example: [S3A0075 sets volume to 75
[ +3A
Audio volume up
[ -3A
Audio volume down
[ S3E 000#
Audio mute (speakers/headphones)
0 = not muted, 1 = muted
Example: [S3E0001 mutes the audio output
[ S4A 000#
Main input selection
0 = TV
1 = Input1
2 = Input2
3 = Input3
4 = Input4
6 = RGB
8 = HDMI1
9 = HDMI2
Example: [S4A0006 selects RGB