Reliability test items
No. Test item Conditions
1 High temperature storage test
Ta=60
240h
2 Low temperature storage test
Ta=-25
240h
3 High temperature
& high humidity operation test
Ta=40
; 95%RH 240h
(No condensation)
4 High temperature operation test
Ta=50
240h
(The panel temp. must be less than 60
)
5 Low temperature operation test
Ta=0
240H
6 Vibration test
(non- operating)
Frequency : 10
57Hz/Vibration width (one side) : 0.075mm
: 58
500Hz/Gravity : 9.8m/s
2
Sweep time : 11 minutes
Test period : 3 hours
(1 hour for each direction of X,Y,Z)
7 Shock test
(non- operating)
Max. gravity : 490m/s
2
Pulse width : 11ms, sine wave
Direction :
±
X,
±
Y,
±
Z,
once for each direction.
Result Evaluation Criteria
Under the display quality test conditions with normal operation state, these shall be no change
which may affect practical display function.