Sony 1500AP VCR User Manual


 
69
Menu Contents
Chapter 4 Menu Settings
VITC POS SEL-1 [> VITC pos-1]: Select a line to insert the
VITC in.
Note
You can insert the VITC signal in two places. To insert it in two
places, set both this item and also VITC POS SEL-2.
(For DSR-1500A)
20 LINE [>> 20 line] to 12 LINE [>> 12 line]: Select any line
from 12 to 20.
Factory default setting: 16 LINE [>> 16 line]
(For DSR-1500AP)
22 LINE [>> 22 line] to 9 LINE [>> 9 line]: Select any line
from 9 to 22.
Factory default setting: 19 LINE [>> 19 line]
VITC POS SEL-2 [> VITC pos-2]: Select a line to insert the
VITC in.
Note
You can insert the VITC signal in two places. To insert it in two
places, set both this item and also VITC POS SEL-1.
(For DSR-1500A)
20 LINE [>> 20 line] to 12 LINE [>> 12 line]: Select any line
from 12 to 20.
Factory default setting: 18 LINE [>> 18 line]
(For DSR-1500AP)
22 LINE [>> 22 line] to 9 LINE [>> 9 line]: Select any line
from 9 to 22.
Factory default setting: 21 LINE [>> 21 line]
VITC OUTPUT [> VITC out]: Select the time code to be output
as VITC.
OFF [>> OFF]: Do not output VITC.
TC [>> TC]: Output TC after converting it into VITC.
*VITC [>> VITC]: Output VITC.
EE OUT PHASE [> EE out]: Determine the output phase for
the LTC signal output from the TC OUT connector when
recording time code and in STOP REC mode (forced EE
mode).
*MUTE [>> mute]: Mute the output.
THROUGH [>> through]: Output the time code input to the
TC IN connector as it is. (
See example configuration on
page 75
.
)
VIDEO INPUT PHASE [>> V input]: Output the time code
with the same phase as the input video signal phase.
(See example configuration on page 75.)
VIDEO OUTPUT PHASE [>> V output]: Output the time code
with the same phase as the output video signal phase.
(See example configuration on page 76.)
MUTE IN SRCH [> Mute in SR]: Select whether to mute the
output from the TC OUT connector in search (jog/shuttle)
mode.
OFF [>> OFF]: Do not mute.
*ON [>> ON]: Mute.
TAPE PROTECTION [Tape protct]: Settings related to tape
and video head protection
Description of settings
FROM STOP [> From STOP]:
Set the time to switch from
stop mode to tape protection
mode.
STOP TIMER [>> STP
timer]: Set the time to
switch from stop mode
to tape protection
mode.
0.5 SEC [>>> 0.5 sec] to 5 MIN [>>> 5 min]: Select time from
12 settings ranging from 0.5 second to 5 minutes in steps
of 0.1 second.
Factory default setting: 1 MIN [>>> 1 min]
FROM STILL [> From STILL]:
Set the time to switch from
still search mode to tape
protection mode. Also select
the type of tape protection
mode.
STILL TIMER [>> STL
timer]: Set the time to
switch from still search
mode to tape
protection mode.
0.5 SEC [>>> 0.5 sec] to 5 MIN [>>> 5 min]: Select time from
12 settings ranging from 0.5 second to 5 minutes in steps
of 0.1 second.
Factory default setting: 1 MIN [>>> 1 min]
NEXT MODE [>> Next
mode]: Select the type
of tape protection
mode to follow still
search mode when the
time set with the STILL
TIMER menu item
elapses.
*STEP FWD [>>> Step]: The tape is advanced at
1
/
30
times
normal speed for about 2 seconds.
STANDBY OFF [>>> STANDBY]: Standby off mode
TIME CODE [Time code]: Settings related to the time code
generator
Description of settings