Sony HKDV-507 DVD VCR Combo User Manual


 
Appendix A-33
Appendix
Item number Settable rangeItem
627 CHAR WARNING
DISPLAY at dual
line mode
[off]
on
When item 626 is set to anything other than time data only,
this item specifies whether warning messages flash on the
second line or not.
off: Warning messages do not flash.
on: If a warning message exists, it flashes.
Notes
Messages that have been cleared are not displayed. For
more information about clearing warning messages, see
Clearing warning messages on page A-12.
When there are multiple warning messages, each
message flashes twice before it is replaced by the next
message.
628
REMAIN TIME
DISPLAY
[off]
10min
on
Sets whether to display remaining time on the tape in
superimposed charecter position.
off: Do not display remaining time.
10 min: Display remaining time when it is 10 minutes or
less.
on: Always display remaining time.
Notes
The remaining time on the tape is not displayed when no
cassette is inserted. The remaining time is not also
displayed until the VTR finishes detecting the diameter of
the wound tape and estimating the remaining time
immediately after the cassette is inserted.
Function
630
TC CONVERSION
at 25F off-speed
PB
[off]
on
Specifies whether or not to convert the 24 frames time code
to the 25 frames time code when off-speed playing back the
cassette tape recorded in the 24F mode with the 25F mode.
off: Does not convert the 24 frames time code to the 25
frames time code.
on: Converts the 24 frames time code to the 25 frames time
code.
Note
This setting is only active when the field frequency is 25 Hz.
631 ORIGINAL TC
display
[off]
on
When item 630 is set to on, this setting specifies whether
the 24-frame time code is displayed or not on the control
panel of the VTR before conversion.
off: The 24-frame time code is not displayed before
conversion.
on: The 24-frame time code is displayed before conversion.
The type of time code type displayed is specified by item
603.
632
JUMPING TC
select
[–3H]
2H
1H
+1H
+2H
+3H
0H
When the 24-frame time code is converted to 25-frame time
code, this setting specifies the loopback point (JUMPING
TC) with respect to the reference point for conversion
(STARTING TC).
3H: The JUMPING TC is set 3 hours before STARTING
TC.
2H: The JUMPING TC is set 2 hours before STARTING
TC.
1H: The JUMPING TC is set 1 hour before STARTING TC.
+1H: The JUMPING TC is set 1 hour after STARTING TC.
+2H: The JUMPING TC is set 2 hours after STARTING TC.
+3H: The JUMPING TC is set 3 hours after STARTING TC.
0H: The JUMPING TC is set 1 frame before STARTING TC.