Sony RM-NX7000 Universal Remote User Manual


 
236
Troubleshooting
Continued
Symptom
The display does not change to the
setting display even when you press
the [SET] key.
The display does not change to the
application display even if you
press the [APP] key.
The display does not change even if
you press the Component key
shown in the Home display.
You cannot operate a component
even if you press the [REC] key.
The key to which a macro has been
set does not appear.
Remedy
• The [SET] key should be pressed for 2 seconds
or longer. If you press the [SET] key for 2
seconds or longer, you can enter the setting
display.
• The E mark may be shown. If the batteries are
running out, you cannot enter the setting
display. Connect the supplied AC power
adaptor. Or, because in the setting display,
power consumption increases when saving or
updating data, it is recommended to use the
Remote Commander with the supplied AC
power adaptor connected.
• The [APP] key should be pressed for 2 seconds
or longer. If you press the [APP] key for 2
seconds or longer, you can enter the setting
display.
• The E mark may be shown. If the batteries are
running out, you cannot enter the application
display. Connect the supplied AC power
adaptor. Or, because of the application display,
power consumption increases. It is therefore
recommended to use the Remote Commander
with the supplied AC power adaptor connected
in this instance.
• No key is assigned that is available in the first
page of the component. Edit to assign, in the
setting mode, a key that is available in the first
page.
• The key corresponding to the sound or image
recording is set so that a signal is transmitted
after the key is kept pressed for 2 seconds or
longer to prevent accidental operation. The
press time (the pressing time of the function
key until the operation (action) is executed) can
be changed by the supplied “NAVITUS
Design.” You can also change the press time of
a Component key or a function button.
• The setting contents of the macro (action) may
have been changed while editing, and the
macro may not be correctly linked. Check the
setting procedure of the macro, and set again.