Toshiba L43 Flat Panel Television User Manual


 
36
English
CONTROLS AND FEATURES
White Balance-Window Display
This feature displays a special Window Pattern to be used
when adjusting white balance with a measuring device.
a In the Expert Picture Settings menu, press B / b
to select White Balance and press OK.
b Press B / b to select Window Display and press
c and B / b to select On and press OK.
White Balance-Setting Type
You can choose from two types of White Balance
adjustment.
a In the Expert Picture Settings menu, press B / b
to select White Balance and press OK.
b Press B / b to select Setting Type and press OK.
c Press C / c to select 2P or 10P and press OK.
White Balance-2P White Balance
a Press b to select 2P White Balance and press
OK.
b Press B / b to select Red-Offset, Green-Offset,
Blue-Offset, Red-Gain, Green-Gain, or Blue-
Gain.
A white square will appear on the screen.
c Press C / c to adjust and press OK.
White Balance-10P White Balance
a Press b to select 10P White Balance.
b Press B / b to select IRE, Red, Green, or Blue.
c Press C / c to adjust and press OK.
NOTE: The adjustments made for Red / Green / Blue are
stored separately for each IRE setting. (There are ten IRE
settings from 10 to 100.)
Gamma Calibration
Toshiba has integrated picture calibration systems into its
LCD televisions. Now you can enjoy the benefits of
automatically calibrated gamma and white levels.
In order to take advantage of these features the Toshiba
colour analyzer TPA-1 is required.
a In the Expert Picture Settings menu, press B / b
to select Gamma Calibration and press OK.
b Press B / b to select Apply Calibration and
press
c and B / b to select Enabled and press
OK.
c Press B / b to select Auto Gamma Calibration
and press OK.
d Connect the USB colour analyzer to the USB 1 or
USB 2 port.
e Input the target value and place the USB colour
analyzer over the square on screen.
f Highlight Start and press OK.
Auto Gamma Calibration will start.
Please wait until you see “Auto Gamma Calibration
has been completed.” on screen.
To return to factory setting
a Highlight Reset and press OK.
xy
Auto Gamma Calibration
Please input the target value and place the USB colour analyser over
the square.
Target Colour Temperature
Target Gamma
0.313
2.4
0.329 (D65)
ResetStart