Toshiba TLP511U Projection Television User Manual


 
5-8
5-14. Applicable Signal
Various kinds of signals are used as the applicable
signals in the preset mode (standard value) as shown in
Table 5-14-1. For the signals not fit to the preset modes,
a user mode is provided.
In the preset modes, the applicable signals are based on
the VESA standard, so the sample frequency (CLOCK
adjustment in the panel menu) is not used, but the
adjustment is allowed only in the user mode.
Mode
NTSC
PAL
V60
V72
V75
V85
M13
24K
T70
T70
T70
T70
T85
T85
T85
S56
S60
S72
S75
S85
M16
X60
X70
X75
X85
M21
SXGA1
SXGA2
In other mode, the signal line number is detected to allow
the separate adjustment in the VGA system (basically
effective for line number of 480 lines), SVGA system
(basically effective for line number of 600 lines) and
XGA system (basically effective for line number of 768
lines).
In the user mode of SGA system (900 line system and
1024 line system), the input signal is applicable to the
plain display mode. That is, the signal is displayed in
different two ways owing to the line number in vertical
direction.
Table 5-14-1 Applicable signal
Signal
Content
NTSC
PA L
VGA 60 Hz
VGA 72 Hz
VGA 75 Hz
VGA 85 Hz
MAC-13”
PC98-STD
VGA 70 Hz
VGA 70 Hz
VGA 70 Hz
VGA 70 Hz
VGA 85 Hz
VGA 85 Hz
VGA 85 Hz
SVGA 56 Hz
SVGA 60 Hz
SVGA 72 Hz
SVGA 75 Hz
SVGA 85 Hz
MAC-16”
XGA 60 Hz
XGA 70 Hz
XGA 75 Hz
XGA 85 Hz
MAC-21”
1152 system
1280 system
H
664
756
640
640
640
640
640
640
720
720
640
640
640
640
720
800
800
800
800
800
832
1024
1024
1024
1024
1152
1152
1280
V
484
574
480
480
480
480
480
400
350
400
350
400
350
400
400
600
600
600
600
600
624
768
768
768
768
870
864
1024
H (kHz)
15.734
15.625
31.470
37.861
37.500
43.269
35.000
24.830
31.470
31.470
31.470
31.470
37.861
37.861
37.927
35.156
37.879
48.077
46.875
53.674
49.724
48.363
56.476
60.023
68.677
100.000
108.000
135.000
Resolution Frequency All Operation
V (Hz)
59.940
50.000
59.940
72.809
75.000
85.008
66.667
56.420
70.020
70.020
70.020
70.020
85.080
85.080
85.039
56.250
60.317
72.188
75.000
85.061
74.550
60.004
70.069
75.029
84.997
68.653
67.500
79.976
Clock
(MHz)
12.590
12.500
25.175
31,500
31.500
36.000
30.240
21.053
28.322
28.322
28.322
28.322
31.500
31.500
35.500
36.000
40.000
50.000
49.500
56.250
57.283
65.000
75.000
78.750
94.500
75.030
75.000
75.025
H
800
800
800
832
840
832
864
848
900
900
800
800
832
832
936
1024
1056
1040
1056
1048
1152
1344
1328
1312
1376
1456
1600
1688
V
525
625
525
520
500
509
525
444
450
450
450
450
445
445
446
625
628
666
625
631
667
806
806
800
808
915
900
1066
Sync
H/V
N/N
N/N
N/N
N/N
N/N
N/N
N/N
N/N
P/N
N/P
P/N
N/P
P/N
N/P
N/P
N/N
N/N
N/N
N/N
N/N
N/N
N/N
N/N
N/N
N/N
N/N
N/N
N/N
Corre-
spondence
O
O
O
O
O
O
O
O
D
D
O
O
O
O
D
O
O
O
O
O
O
O
O
O
O
X
X
X
Remarks
Video input
Video input
Plain display
Plain display
Plain display
In the sync column of Table 3-14-1, P shows the posi-
tive polarity and N shows the negative polarity.
In the operation column, O shows a standard mode, D
shows pull-in mode, X shows plain display mode.