TROUBLESHOOTING SUGGESTIONS
If a Media Converter fails, ask the following questions:
1. Is the Power LED on the media converter illuminated?
NO
Is the power adapter the proper voltage and cycle frequency
for the AC outlet? NOTE: Refer to the “Power Supply
Requirements” on the back page.
Is the power adapter properly installed in the media converter
and in the outlet?
Contact Technical Support: (800) 260-1312/(800) LAN-
WANS.
YES
Proceed to step 2.
2. Is the UTP/STP LED illuminated?
NO
Check twisted pair cables for proper connection.
Check RJ-45 connector for correct twisted pair cable
configuration.
Contact Technical Support: (800) 260-1312/(800) LAN-
WANS.
YES
Proceed to step 3.
3. Is the Fiber LED illuminated?
NO
Check fiber cables for proper connection.
Verify that TX and RX cables on media converter are
connected to RX and TX ports, respectively, on other device.
Contact Technical Support: (800) 260-1312/(800) LAN-
WANS.
YES
Contact Technical Support: (800) 260-1312/(800) LAN-
WANS.
3. Connect second PS-CF-01 media converter to terminal equipment
through copper cable.
UTP to RJ-45 Connector:
If connecting to RJ-45 connector on terminal equipment (as on
front of PowerStar™ III or PowerStar™ IV):
Connect male RJ-45 plug connector to female RJ-45 connector
marked “link” on terminal equipment.
UTP to Twinax Connector:
If connecting to twinax connector on terminal equipment (as on
back of PowerStar™ III or on PowerStar™ IV with Twinax SIC):
NOTE: Install TRANSITION Networks balun part number: 3-4554
between RJ-45 cable and Twinax connector.
Install balun at terminal equipment Twinax connector.
Connect male RJ-45 plug connector to balun.
4. Connect PS-CF-01 media converter(s) to power.
Locate correct power supply adapter for site installation. (See
back page.)
Connect PS-CF-01 power connector at end of power supply
adapter cord to PS-CF-01 power receptacle.
Connect 2-prong or 3-prong external power connector on
other end of power supply adapter cord to external AC power.
3
6
PS-CF-01