Serial Communications
62 Vidikron PlasmaView Owner’s Operating Manual
PRE
L
IMINAR
Y
FMKS00 46 4D 4B 53 30 30 – – Sets the TEST PATTERN to OFF.
FMKS02 46 4D 4B 53 30 32 – – Sets the TEST PATTERN to INVERSE
(negative-positive inversion).
FMKS03 46 4D 4B 53 30 33 – – Turns ON the WHITE test pattern.
FMKS04 46 4D 4B 53 30 34 – – Turns ON the RED test pattern.
FMKS05 46 4D 4B 53 30 35 – – Turns ON the GREEN test pattern.
FMKS06 46 4D 4B 53 30 36 – – Turns ON the BLUE test pattern.
FMKS07 46 4D 4B 53 30 37 – – Turns ON the YELLOW test pattern.
FRCS00 46 52 43 53 30 30 – – Sets FRC to SCALER.
FRCS01 46 52 43 53 30 31 – – Sets FRC to NORMAL.
GSL 47 53 4C 000 255 Adjusts the GREEN sidebar level.
IDC 49 44 43 – – Clears the display ID number (resets to
“ALL”); for example,
01IDC.
IDS 49 44 53 – – Sets the display ID number; for example,
01IDS sets the display ID to 01h.
Note: IDS only works if the display ID
number has been cleared (with IDC) or has
not been previously assigned.
IPRS01 49 50 52 53 30 31 – – Sets the DISPLAY PROFILE to NORMAL.
IPRS02 49 50 52 53 30 32 – – Sets the DISPLAY PROFILE to PURE.
IPRS03 49 50 52 53 30 33 – – Sets the DISPLAY PROFILE to
MONOTONE.
IPRS04 49 50 52 53 30 34 – – Sets the DISPLAY PROFILE to HIGH
CONTRAST.
LESS00 4C 45 53 53 30 30 – – Sets FRONT L.E.D. to OFF.
LESS01 4C 45 53 53 30 31 – – Sets FRONT L.E.D. to ON.
OSDS00 4F 53 44 53 30 30 – – Sets OSD DISPLAY to OFF.
OSDS01 4F 53 44 53 30 31 – – Sets OSD DISPLAY to ON.
OSSS01 4F 53 53 53 30 31 – – Sets OSD SIZE to LARGE.
OSSS02 4F 53 53 53 30 32 – – Sets OSD SIZE to SMALL.
Table 6-1. Serial Commands (continued)
Command Value Range
Description
ASCII HEX Minimum Maximum
Notes:
1. When making input-specific adjustments such as to image quality, screen position/size or audio
sub-volume, select the input you wish to affect before making such adjustments.
2. These settings are not stored in memory.