AC/DC Distribution Panel
The XADC may be pre-installed with an AC/DC Distribution Panel. The panel is
available in two configurations which provides the approved wiring boxes for AC
and DC connections:
30A (Part Number: 810-0030-00 XADC P30) – eight output breakers
50A (Part Number: 810-0050-00 XADC P50) – 10 output breakers
In each configuration there are also 11 unassigned DC fuses and four reserved
fuses for the battery connections.
Figure 3 and Figure 5 show the main components of the XADC with AC/DC
Distribution Panel.
Figure 2
XADC Internal Components
Item Description
1 AC wiring compartment hole
2 Black AC line cable
3 White AC neutral cable
4 Green AC ground cable
5 Grommet (supplied)
6 Strain relief (not supplied)
7 DC wiring compartment hole ½ in. - 3/8 in. trade size (with ¾ in. knockout)
8DC fuses
9 DC positive (+) and negative (-) connection lugs
POS
(+)
NEG
(-)
1
2
3
4
7
9
8
6
5
Important:
The XADC P30 and XADC P50 panels are not intended for use with rigid
conduit systems.