A SERVICE OF

logo

Main menu
68 Instruction manual GWV
11
gis
Confirm the minute setting with
The time has been set.
Note
The appliance takes no account of summer time.
11.12.3 Displaying appliance specifications
Note
This category is only relevant to the installation
engineer and/or service and maintenance engineer.
The table shows the correct settings.
Bring up the menu to display the appliance
specifications via:
1. :
SETTINGS
.
Confirm with .
2. Scroll to
SPECIFICATIONS
Confirm with .
The display shows the submenu for displaying
appliance specifications.
3. Scroll with to the section to be displayed, for
example
REGULATION INTERVAL
.
The relevant display appears.
TIME
15»45
GWV 120
Ignition rotation
speed (rpm)
1620
Working revs 1
(partial load)
(rpm)
2040
Working revs 2 (full
load)
(rpm)
2340
Adjustability
(
o
C)
40 - 85
GWV 150 GWV 200
Ignition rotation
speed (rpm)
1500 1800
Working revs 1
(partial load)
(rpm)
2340 2460
Working revs 2 (full
load)
(rpm)
2700 2820
Adjustability
(
o
C)
40 - 85 40 - 85
MENU
WEEK PROGRAM
^ EXTRA PERIOD
ȻSETTINGS
SETTINGS
LANGUAGE
^ DAY/TIME
ȻSPECIFICATIONS
SPECIFICATIONS
»
REGULATION INTERVAL
^
IGNITION SPEED
È
WORKING SPEED
REGULATION INTERVAL
40
_
85ÉC