Device with concentric ue gas discharge material
According to the table the maximum length is 20 metres and the allowed
number of 90° bends is 5. Both requirements are met.
Speci cations
Caution
A.O. Smith prescribes the use of a roof or wall ue terminal approved for
the device with the C13 and C33 device types. Use of an improper roof or wall
ue terminal may lead to an error.
Speci cation of concentric wall ue terminal C13
Subject Description
Wall ue terminal set:- 1x Wall ue termi-
nal (incl. wall plate & clamping strip)
- 1x Pipe 500 mm
- 1x Bend 90°
Item no.: TWI 35-130: 0302 515
(1)
TWI 45-190: 0302 515
(1)
Construction: Concentric
Manufacturer: Muelink & Grol
Type: M2000 MDV SEC
Piping material Construction: Concentrique
Flue gas discharge: Thick-walled aluminium with lip-ring sealing
Air supply: Thin-wall galvanised sheet steel
Pipe diameters Flue gas discharge: TWI 35-130: Ø 80 mm
TWI 45-190: Ø 80 mm
Air supply: TWI 35-130: Ø 125 mm
TWI 45-190: Ø 125 mm
(1) It is not allowed to use any other wall ue terminal. You can order the wall ue terminal mentioning the item
number with A.O. Smith, manufacturer or wholesaler’s.