General Problems:
Q: The OSD menu does not display a on a port where a computer is connected
and powered up.
A:
RESET the OmniView
PRO by simultaneously pressing the BANK/SCAN and
CHANNEL buttons on the front panel. Access the OSD menu again and it should
have re-detected all the active ports.
Q: When cascading, the MASTER unit does not see the slave unit(s).
A:
Refer to the Hardware Installation section for information on how to properly
connect the daisy-chain cable.
Make sure that the daisy-chain cable that you are using is the F1D108-CBL. Using
any other cable will not guarantee proper operation or video quality.
RESET the MASTER OmniView
PRO.
Although a power supply is not necessary to make the slave unit work, try adding
a power supply.
Monitor/Video Problems:
Q: I am getting ghosting, shadowing or fuzzy images on my monitor.
A: Check the cables and make sure they are inserted properly.
Your resolution and/or refresh rate is extremely high, or your cable is too long.
Replace your VGA cables with coaxial, double-shielded cables such as Belkin
A3H981-XX.
Check to make sure that the power adapter is plugged in and is working properly. It
must be 12VDC, 1000mA minimum. Make sure the power switch is on.
Lower you refresh rate and/or screen resolution settings.
Keyboard Problems:
Q: The keyboard is not detected, or a keyboard error is reported during boot-up.
A: • Check the cables and make sure they are inserted properly in the correct ports.
Check to make sure that the power adapter is plugged in and is working properly.
It must be 12VDC, 1000mA minimum. Make sure the power switch is on.
RESET the OmniView
PRO by simultaneously pressing the BANK/SCAN and
CHANNEL buttons on the front panel. Access the OSD menu again and it should
have re-detected all the active ports.
Do not press any keys on the keyboard while the selected computer is booting
up. This is true for any PC, whether stand-alone or connected to a KVM switch.
Q: The computers boot up fine, but the keyboard does not work.
A: Check the cables and make sure they are inserted properly in the correct ports.
Make sure the keyboard works when directly plugged into the computers.
Try a different keyboard, but use only 101, 102 or 104-key keyboards.
Make sure that the keyboard driver is for 101, 102 or 104-key keyboards, and not
old XT keyboards.
Check to make sure that the power adapter is plugged in and is working properly.
It must be 12VDC, 1000mA minimum. Make sure the power switch is on.
RESET the OmniView
PRO by simultaneously pressing the BANK/SCAN and
CHANNEL buttons on the front panel. Access the OSD menu again and it should
have re-detected all the active ports.