Flow Restrictor Valve Replacement
If the flow restrictor valve Figure 4-4 needs to be removed or replaced, it is important that
it be properly reinstalled. The valve will be marked either with an arrow or with the word
“IN”. If marked with an arrow, the arrow must point away from the hydraulic cylinder
port. If marked with the word “IN”, the end of the valve marked “IN” must be toward the
hydraulic cylinder port. Only a 1/4 inch NPT hydraulic elbow should be connected be-
tween the hydraulic cylinder port and the end of the flow restrictor valve.
Improper installation of the flow restrictor valve or the use of the wrong size elbow will
permit widely varying rates of descent and may result in near free-fall in case of hose
failure.
HYDRAULIC
CYLINDER
PORT
¼ INCH NPT
HYDRAULIC
ELBOW
FLOW
RESTRICTOR
VALVE
HYDRAULIC
CYLINDER
Figure 4-4. Flow Restrictor Valve