![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/c9/0c96a5c7-9289-3074-b162-5e4234d8df88/0c96a5c7-9289-3074-b162-5e4234d8df88-bg8.png)
www.desatech.com
114370-01D8
INSTALLATION
Continued
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections, internal and
external to unit, for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an
open ame to check for a leak.
Apply a noncorrosive leak detec-
tion uid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect log set with its individual equip-
ment shutoff valve from gas supply piping
system.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping system by either us-
ing compressed air or opening main gas valve
located on or near gas meter.
4. Check all joints of gas supply piping system.
Apply noncorrosive leak detection uid to gas
joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect log set and equipment shutoff valve
to gas supply. Check reconnected ttings for
leaks.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 5).
2. Pressurize supply piping system by either us-
ing compressed air or opening main gas valve
located on or near gas meter.
3. Check all joints from gas meter to equip-
ment shutoff valve (see Figure 6). Apply
noncorrosive leak detection uid to all joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
Figure 5 - Equipment Shutoff Valve
Equipment
Shutoff
Valve
Open
Closed
Figure 6 - Checking Gas Joints
HEARTH KIT ASSEMBLY AND
INSTALLATION
1. Determine which side the gas line will be
coming into the replace.
NOTICE: Unit comes preassembled with gas
inlet on right side. If your replace gas supply
is on the left, gas inlet should be repositioned
to left side of unit.
2. If gas supply line in your replace is on the right
side, continue to step 3. If not, see Reposition-
ing the Gas Inlet to the Left Side of Unit.
3. Install adapter tting that comes with log set
into replace gas supply pipe (see Figure 7).
Seal using thread sealant.
Figure 7 - Connecting Adapter to Gas
Supply
Gas
Connector
Tube
Adapter
Fitting
Gas Inlet
Fitting
Equipment
Shutoff Valve
Gas Meter