Product Description Basic Specifications 25
1.2.9 Electrical Specifications
AC LINE NOISE
Pulse width: 50 to 1000 ns
Pulse polarity: + / -
Repetition: Asynchronous
Modes: Common / Normal
Voltage: 1KV
(Parts must be able to withstand 2KV without
damage)
TRANSIENT OUTAGE
DIP 100% (at rated voltage - 10%) 1 cycle
(No abnormal print quality)
ELECTROSTATIC TOLERANCE
Up to 10KV: No hard error, no user-nonrecoverable
software error
Up to 15KV: No damage to parts
SURGE CURRENT
1/2-cycle / Not above 50A
INSULATION RESISTANCE
10M
or more
DIELECTRIC STRENGTH
Insulation shall not break down when the following voltage is applied
between primary circuit and chassis for 1 minute:
100V version: AC1000V
200V version: AC1500V
LEAKAGE CURRENT
3.5mA or less