z Paper path lower-side (glasses: 2 sheets)
The glass should not have to be removed as it is
designed to block paper dust. Remove and clean the
glass only if the scanner is being used in an environment
with large amounts of paper dust and vertical streaks
appear on the scanned image even after cleaning the
glass. Be careful not to let any paper dust in when remov-
ing the glass. Clean the glass on paper path lower-side
as follows:
1 Loosen the screw until the glass can be lifted.
2 Tilt the glass to the angle as shown above.
3 Remove the glass as you slide it to the left.
4 Clean the removed glass.
Glass (removable)
Glass (not removable)
2
1
3
5 From the gap where the glass was attached, clean
the other layer of glass inside, using a cotton swab
or something alike.
Vertical streaks may appear on the scanned image when
the glass is dirty.
Cross-section
Glass