A SERVICE OF

logo

16
IN
R
DC 12 V
GND
Preparation (Step 1 Connection/Installation)
This terminal is for connecting with an alarm annunciator such as an indicator, a lamp
or a buzzer.
4. Connection of LAN Cables
1-1 Connecting Cables (Continued)
VN-C655
OUT
Terminal
Alarm Device
Connection
Example
(Alarm Output
Equivalent Circuit)
Grounding
Te r minal
Note
When using 100 BASE-TX, ensure to use a Category 5 (or higher) cable.
Caution
Connect the VN-C655 grounding terminal to
the one of the annunciator.
Caution
There are a few types of LAN board for which
a cross-over cable cannot be used. Check
the specifications of the LAN board to be used
before performing connection.
Output Requirements
Equivalent to NPN open collector output
(The output logic is set with [V.Networks Setup
To ol.])
Allowed applied voltage: DC 12 V max.
Allowed input current: 50 mA
Momentary output: 1 to 5000 ms
(The duration is set with [V.Networks Setup
To ol.])
Connect the camera to a hub or a PC by using a LAN cable.
For hub connection
Use a straight cable.
For PC connection
Use a cross-over cable.
C655(B)_p2-22 05.3.16, 1:21 PM16