E-EQ-MX3MCPLUS-F-ARC MX3 Multi-Charger Plus User’s Guide
Battery Capacity
Compare the mAh reading obtained at the end of the analyze process with the battery pack’s
specified capacity. If the analysis indicates a value equal to or greater than the specified capacity,
the battery pack is at 100% capacity. A battery pack with less than 80% capacity provides a
significant reduction in the length of time it can power the unit.
LXE Battery Pack Part Number
156213-0001
2381A376BATT1600
158224-0001
MX3A378BATT
and
159922-0001
MX3A380RFIDBATT
Construction
Lithium Ion Lithium Ion
Specified Capacity
1400mAh 1800mAh
80% of Specified Capacity
1120mAh 1440mAh
Battery Fault
On rare occasions, the charge or analysis process may fail. If this occurs, note the information on
the LCD screen. If the problem cannot be resolved from the troubleshooting information in the
Appendix, please contact LXE Customer Support.
DISCHARGE
1
ANALYZE
BAT. FAULT
E04
11.2V
Figure 14 LCD Screen, Battery Fault
The LCD indicates:
• The process when the fault occurred (DISCHARGE; 1; ANALYZE). In this case,
the fault occurred during the discharge cycle of the analyze process.
• A battery fault has occurred (BAT. FAULT).
• An error message indicating the nature of the fault (E04). Please review the
Appendix or contact customer support for more information on the error code.
• The current battery voltage (11.2VDC).
Error Message Cause Explanation
E01
Power supply under-voltage
Battery over-voltage
E02 Timeout
E03
Soft start rate incorrect
Soft start not ready
Battery open circuit
90 minute timeout
E04 Discharge rate incorrect