6.4 GT05
6.4.1 General Specifications
Item
3.6 W or less (150 mA or less)
2.4 W or less (100 mA or less)
Insulation method of
Transformer insulation
°
20 to 85% RH (at 25 °C, non-condensing)
°
°
Breakdown voltage
Note1)
Between [power supply terminals] and [case]
500 V AC for 1 minute, Cutoff current 10mA (at default setting)
Insulation resistance
Note1)
Between [power supply terminals] and [case]
100 MΩ or more, 500 V DC, measured with megohmmeter (at default
setting)
Vibration resistance
10 to 55 Hz (1-minute cycle)
Amplitude: 0.75 mm, 10 min on 3 axes
98 m/s
2
or more, 4 times on 3 axes
EN61131-2 (EMC Directive)
Noise immunity
1000 V [P-P] or more, Pulse width 50 ns, 1µs between power supply
terminals (based on in-house measurements)
Note2)
Protective construction
IP65 (Initial value, evaluated by us)
Dustproof and drip-proof from front panel only (packing used on panel
Note3)
Note1) Not isolated between the USB port, COM. port and the internal digital circuit.
Note2) When using our exclusive cable.
Note3) When reattaching, replace waterproof packing.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net