116
The columns in the table indicate the states as shown in the
figure.
MON: Monitor number
CAM: Logical camera number (01 to 99)
Recorder number (R0 to R4)*
No number indicates no camera is
selected.
MODE: Lists the display mode on the
monitors.
SPOT: Spot mode
Tnn: Tour Sequence mode (nn is the
tour sequence number.)
CAM: Camera Setup mode
SET: WJ-SX150A Setup mode
ALARM: Alarm Active mode
ACK: Alarm ACK mode
VLD H: Video Loss History Table
ALM H: Alarm History Table
SYS S: System Status Table
RECORDER: Recorder mode**
KB: Lists the system controller name
(K1 to K4) or PSD.
OPE: Lists the operator number
PRI: Lists the priority number
* R0 to R4 shows the following.
Recorder number Recorder
R0 Master recorder
R1 Slave 1 recorder
R2 Slave 2 recorder
R3 Slave 3 recorder
R4 Slave 4 recorder
** When this parameter is selected, a recorder number is
displayed in the CAM area.
3. To exit from the mode, press the CLEAR button.
● Moving the Camera Title Display
Move the joystick while holding down the OSD, SHIFT and
2 buttons. (2) will move to the desired direction.
● Moving the Event Display
Move the joystick while holding down the OSD, SHIFT and
3 buttons. (3) will move to the desired direction.
● Moving the Monitor Status*
Move the joystick while holding down the OSD, SHIFT and
4 buttons. (4) will move to the desired direction.
* Monitor number, controller number and monitor mode
● Moving All the Items
Move the joystick while holding down the OSD, SHIFT and
5 buttons. (1), (2), (3), and (4) will move to the desired
direction.
■ System Status Table
The table shows the current system status.
1. Select the desired monitor. (Refer to p. 106 Monitor
Selection.)
2. Press the button 9 while holding down the OSD button.
"OSD" will appear on the LED display, and the SYSTEM
STATUS table will appear on the active monitor as
shown in the figure.