52
Pattern 4: Master, Slave 1 to 4 are connected in the system.
Note: Before connections, make sure all the units have the same firmware version. You can see the firmware version of each
unit in SETUP MENU. (Refer to pp. 72 and 73 710 MASTER-SLAVE.) In case there is a version difference, update the
firmware of each unit to the newest using a CD-ROM. (Refer to pp.58 to 60 FIRMWARE UPDATE.)
● Preparation
Prepare the following items besides standard accessories.
• Personal computer x 1 (Refer to p. 79 Platform for details on system requirements.)
• 9-pin D-sub crossing cable x 1 (Used for connection between the PC and the Master unit)
• Phillips screwdriver x 1 (Used for opening the front panel and setting unit numbers)
• Coaxial cable* (Used for connection of the Master and Slave units)
• Cable Kit WV-CA48/10K* (Used for connection of more than one Slave unit)
* Necessary number will differ depending on the connection pattern.
● Unit Number Selection
Set the unit number selector of each unit to determine Master and slave n*. (Refer to the illustration and diagram in p. 24.)
*n is a unit number.