D 13373.08
NOVEMBER 2007
MPS
Table of
Contents
TANDBERG MPS
ADMINISTRATOR GUIDE
PRI T1 (US only)
Network Service Facility (NSF) can be configured to mode Off (i.e. NSF not
used – default) or mode On with any value between 0 and 31, to describe
the service facility on the PRI/T1 line.
ISDN Aggregation Standards
H.2211. Frame Structure from 64 (56*) kbps to 128 kbps
ISO 138712. BONDING, Mode 1 from 64 (56*) kbps to 2 Mbps
H.221
For bit rates from 56 kbps up to 128 kbps (1 or 2 channels).•
The maximum relative delay difference between the 2 B-channels is 0.6 •
second.
BONDING
ISO 13871, BONDING Mode 1 for bit rates from 56 kbps up to 2 Mbps •
(1 to 30 channels).
The maximum relative delay difference between B-channels is 0.5 sec-•
ond (i.e. to compensate for different routing of channels).
Standard bandwidths on H.320
30ch – 24 – 23 – 18 – 12 – 8 – 6 – 5 – 4 – 3 – 2 – 1
ISDN Channel Setup
The following is a description of how the ISDN channels are set up.
Incoming & Outgoing MCU calls• : Normally the MCU will set up only 1
channel from PRI 1 and build up the channels starting from the bottom
of the last PRI in use.
This will ensure that the MCU always have available channels on the •
first PRI number (which normally should be the MCUs main number).
The TANDBERG MPS supports simultaneous dial in to the same confer-•
ence on ISDN.
E1/T1 Network Interface Card (IIC-8) (3:3)
PRI T1 (US only) NSF Service Codes
* “0” will still send NSF in the Q931 setup, which may cause calls to fail. Set to mode “off” if not needed.
Ref. 1: AT&T TR 41459 Specification, June 1999, page 76
Ref. 2: Ascend Multiband Plus-T1/PRI, User Documentation, Page 6-8
AT&T Service Code (Ref.1)
Code Service
0 Disable *
1 SDN (including GSDN)
2 Toll Free Megacom (800)
3 Megacom
6 ACCUNET Switched Digital Service (incl. Switched Digital International)
7 Long Distance Service (incl. AT&T World Connect)
8 International Toll Free Service (1800)
16 AT&T MultiQuest
23 Call Redirection Service
Sprint Service Code (Ref.2)
Code Service
0 Reserved
1 Private
2 Inwatts
3 Outwatts
4 FX
5 TieTrunk
MCI Service Code (Ref.2)
Code Service
1 VNET / Vision
2 800
3 PRISM1, PRISMII, WATS
4 900
5 DAL
Network Interfaces
AT&T offers several digital switched services. These include SDN with service code 1 and
ACCUNET with service code 6.
Below is a list of common service profiles. As these profiles may change, contact your