Configuration of the Xanbus AGS
When to use Use this setting after installing the AGS hardware. Selecting
a suitable "Gen Type" automatically configures the AGS to work with the
ignition system and starting requirements of the generator. Consult the
generator manual or contact the generator’s manufacturer for specific
generator starting requirements.
Outcomes Selecting a "Gen Type" from the list automatically
configures the following settings:
• Preheat time
• Preheat end to crank delay time
• Crank time
• Crank retry time
• Starter cool down time
• Generator cool down
• Generator spin down time
• Generator run signal hold time
• Start tries.
If the presets will not work with the desired generator, it may be necessary
to manually configure some of the settings listed above using information
from the generator manufacturer. These settings can be changed in the
CfgGen Menu on page 53.
Type 12 GlowStop with no preheat page 26
Type 13 PulseStop with Relay 3 preheat page 27
Type 14 Run with no preheat and no switched B+
requirement
page 28
a.See “Appendix B: Relay Timing” on page 82 for additional information.
Table 4
Generator Type Descriptions
Option
Description
Mode
For Technical Details, see.
a