Black Box IC026A-R2 TV Converter Box User Manual


 
19
3.3.4 S
ERIAL
P
ARITY
Serial Parity is selected with S2-6 through S2-8. The interface converter
generates the selected parity during serial transmissions but it does not
check parity on data that is received. The factory default is parity disabled.
Figure 3-5. Switch SW2: Selecting the Serial Parity.
3.3.5 S
ERIAL
E
CHO
Serial data sent to the interface converter will be echoed back to the serial
host if SW2-5 is set to the open position. The factory default is Echo Disabled.
Figure 3-6. Switch SW2: Enabling or Disabling Echo.
1 2 3 4 5
6
7 8
OPEN
Echo Disabled
1 2 3 4 5
6
7 8
OPEN
Echo Enabled
Switch
Side
View
DOT
Switch
Side
View
DOT
1 2 3 4 5
6
7 8
OPEN
Mark Parity
1 2 3 4 5
6
7 8
OPEN
Odd Parity
1 2 3 4 5
6
7 8
OPEN
Space Parity
1 2 3 4 5
6
7 8
OPEN
Even Parity
1 2 3 4 5
6
7 8
OPEN
Parity Disabled
CHAPTER 3: Getting Started