Q-See QSD42208 DVR User Manual


 
User Manual for Commercial Series Net DVR
Page 87 Total 121
6.16 RS232 setup
There is one RS-232 port on DVR rear panel. In main menu, move Active Frameto
RS232” icon and perssENTERkey, you enter into “RS232” setup menu:
RS232 menu description
RS-232 parameters: Including baud rate, data bit, stop bit, parity, flow control, etc.
Work mode: The RS-232 can be used as “Console”, PPP” or “Transparent Channel”.
Console: Connect with PC serial port. You can use HyperTerminal or NetTerm to control it.
PPP: Connect Modem, using PSTN to transfer video image.
Transparent channel: Connect serial devices. Remote PC can control these serial devices
through network.
PPP Mode: Only used when work mode is “PPP. There are two options: Activeand
“Passive”. Active means DVR will diaup through PSTN. Active function is not available.
“Passive” means DVR will wait for dialup.
Callback mode: Only used when work mode is PPP. There are two options: By Dialer
and “Preset Tel. This function is not currently available.
Remote IP: Only used when work mode is PPP. This IP is defined for remote PC that will
connect DVR through PSTN.
Local IP: Only used when work mode is “PPP”. This IP is defined for DVR.
Mask: Only used when work mode is PPP. Remote IP and Local IP are in the same sub
net.
Username, password and Verify password: Only used when work mode is “PPP”. Used for