Eiki EIP-3500 Projection Television User Manual


 
67
Optional
accessory
Lamp unit
AH-35001
Removing and Installing
the Lamp Unit
Info
Ensure the lamp unit is removed using the
handle. Ensure the glass surface of the
lamp unit or the inside of the projector are
not touched.
To avoid injury to yourself and damage to
the lamp, ensure to carefully follow the
steps below.
Do not loosen other screws except for the
lamp unit cover and lamp unit.
1 Press on the projector or
on the remote control to put the
projector into standby mode.
Wait until the cooling fan stops.
Warning!
Do not remove the lamp unit from the
projector right after use. The lamp and
parts around the lamp will be very hot
and may cause burn or injury.
2 Disconnect the power cord.
Unplug the power cord from the AC
socket.
Leave the lamp until it has fully cooled
down (about 1 hour).
3 Remove the lamp unit cover.
Turn the projector over. Loosen the user
service screw (1) that secures the lamp
unit cover. Pressing the tab, remove the
lamp unit cover (2).
1
2
User service screw
(for lamp unit cover)
Tab
Tab
AC socket
POWER button