Eiki LC-X71 CRT Television User Manual


 
46
MAINTENANCE
WARNING TEMP. INDICATOR
The Warning Temp. indicator blinks red to let you know the internal
temperature of the projector exceeds a normal level. If the temperature
goes up further, the projector will be turned off automatically and the
Ready indicator goes out. (The Warning Temp. indicator continues
blinking.) After the cooling-off period, the Ready indicator lights on again
and the projector can be turned on by pressing the POWER ON/OFF
button on the top control or the remote control. When you turn on the
projector, the Warning Temp. indicator goes out.
If the Warning Temp. indicator is still blinking, check the following matters:
- The ventilation slots of the projector may be blocked. In such a case,
reposition the projector so that the ventilation slots are not obstructed.
- The air filters may be clogged with dust particles. Clean them by
following the section “AIR FILTER CARE AND CLEANING” on the next
page.
- If the WARNING TEMP. indicator remains on after performing above
checks, the cooling fans or internal circuits may be malfunctioning.
Contact the service station.
TOP CONTROL
When both of the Warning Temp. and Ready indicators are blinking:
Warning Temp.
Indicator
Ready
Indicator
When the projector detects an internal problem, it shuts down automatically and both the Warning Temp. and
Ready indicators start blinking. In this condition, the projector cannot be turned on even if you press the POWER
ON-OFF button on the top control or remote control. If this happens, unplug and reconnect the AC power cord,
and then turn on the projector again to check the operation. If the projector shuts down again or cannot to be
turned on, internal checking and repair is required. Unplug the AC power cord and contact the service station.