LAMP REPLACE COUNTER
Be sure to reset the Lamp replacement counter after the lamp assembly is replaced. When the Lamp
replacement counter is reset, the LAMP REPLACE indicator stops lighting.
NOTE:
Do not reset the Lamp replacement counter until after the projection lamp is
replaced.
Turn the projector on and press the MENU button to display
the On-Screen Menu. Press the POINT LEFT/RIGHT buttons
to move the red frame pointer to the SETTING Menu icon.
Press the POINT UP/DOWN buttons to move the red frame
pointer to Lamp counter and then press the SELECT button.
The next box appears.
1
2
Another confirmation dialog box appears and select [Yes] to
reset the Lamp replacement counter.
4
This projector uses a high-pressure lamp which must be handled carefully and properly. Improper
handling may result in accidents, injury, or create a fire hazard.
Lamp lifetime may differ from lamp to lamp and according to the environment of use. There is no
guarantee of the same lifetime for each lamp. Some lamps may fail or terminate their lifetime in a
shorter period of time than other similar lamps.
If the projector indicates that the lamp should be replaced, i.e., if the LAMP REPLACE indicator lights
up, replace the lamp with a new one IMMEDIATELY after the projector has cooled down. (Follow
carefully the instructions in the LAMP REPLACEMENT section of this manual.) Continuous use of the
lamp with the LAMP REPLACE indicator lighted may increase the risk of lamp explosion.
Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its
lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in
which the projector and lamp are being used.
IF A LAMP EXPLODES, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE TAKEN.
If a lamp explodes, disconnect the projector’s AC plug from the AC outlet immediately. Contact an
authorized service station for a checkup of the unit and replacement of the lamp. Additionally, check
carefully to ensure that there are no broken shards or pieces of glass around the projector or coming out
from the cooling air circulation holes. Any broken shards found should be cleaned up carefully. No one
should check the inside of the projector except those who are authorized trained technicians and who are
familiar with projector service. Inappropriate attempts to service the unit by anyone, especially those who
are not appropriately trained to do so, may result in an accident or injury caused by pieces of broken
glass.
LAMP HANDLING PRECAUTIONS
Lamp counter
Select Lamp counter and this box
appears. Select [Reset], and the
next box appears.
Select [Yes] again
to reset the lamp
counter.
Select [Yes], and then another
confirmation box appears.
Press the POINT UP/DOWN buttons to select Reset and then
press the SELECT button. The “Lamp replacement counter
reset?” appears. Move the pointer to [Yes] and then press the
SELECT button.
3