EverFocus 410M DVR User Manual


 
3.4 ALARM SETUP MENU
In the ALARM SETUP MENU, we define :
(1) ALARM:
ENABLE: Enable alarm detection.
DISABLE: Disable alarm detection.
(2) ALARM TYPE:
N. O. : Normal Open alarm.
N. C. : Normal Close alarm.
N.O. Trans.: When the alarm is triggered, buzzer starts to function no matter how long the alarm
duration is set until you set it back to N.O.
N.C. Trans.: When the alarm is triggered, buzzer starts to function no matter how long the alarm
duration is set until you set it back to N.C.
(3) ACTIVE CAMERA:
Active camera setting, from camera 01~08. You can set the camera which corresponds to the
place where the alarm is located.
Note:The recording camera number in an event depends on the alarm number, and the active camera
images will not be recorded. Example: You assign camera 3 as the active camera to alarm 1.
When the alarm 1 is triggered, camera 3 will be displayed and camera 1 will be recorded.
37