EverFocus EDR-1640 DVR User Manual


 
3.2 CAMERA MENU
The most important recording operation settings are defined in the CAMERA menu.
Before changing the settings in this menu, recording has to be stopped.
Each camera is set individually:
(1) NAME: Enter the video channel description with max. 12 characters each.
Available characters are (select with JOG):
0,1,2,3,4,5,6,7,8,9,
A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,Q,R,S,T,U,V,W,X,Y,Z,
( ) . , + - / and space
(2) PTZ ID: Enter the RS-485 receiver address of a speed dome or telemetry receiver camera
connected to this video channel.
(3) INSTALL / COVERT:
INSTALL (first position) All connected cameras have to be set to ON,
all not connected cameras are set to OFF.
ATTENTION: The manual setting is compulsory, autodetection for connected cameras is not
available!
COVERT (second position): A camera programmed COVERT “ON” will not be displayed, but
recorded at defined parameters.
(4) SEQ(MAIN/CALL): Camera dwell time in sequence operation (automatic switching) for
main (first position) and call (second position) monitor
ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1,
i.e. the address assigned to the dome / receiver in the DVR camera menu
must be 1 below the address set in the dome / receiver itself!
31
CAMERA
CAMERA1
CAMERA2
CAMERA3
CAMERA4
CAMERA5
CAMERA6
CAMERA7
CAMERA8
CAMERA9
SUMMARY
TITLE CH1
PTZ ID 01
INSTALL/COVERT ON/OFF
SEQ (MAIN/CALL) 03/03 SECS
REC QUALITY HIGH
REC SPEED ON TIME ZONE
TP NORMAL EVENT SET
1 5 IPS 25 IPS OFF
2 5 IPS 25 IPS OFF
3 5 IPS 25 IPS OFF
4 5 IPS 25 IPS OFF
5 5 IPS 25 IPS OFF
6 5 IPS 25 IPS OFF
7 5 IPS 25 IPS OFF
8 5 IPS 25 IPS OFF
N 5 IPS 25 IPS OFF
Menu display for EDR-920, EDR1640 identical, but with 16 cameras.