Extron electronic DSC 3G-HD A TV Converter Box User Manual


 
Command ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Output Configuration (continued)
HDCP Status (DSC 3G-HD A only)
Query output
E O 1 HDCP ] X4$ ]
In verbose modes 2 and 3:
Hdcp O 1 * X4$ ]
View HDCP status X4$ of the
digital output.
Input lock (Accu-Frame Lock [AFL]) or SDI Genlock
Disable genlock or
Input AFL
E 0 GLOK } Glok 0 ]
Disable global input lock (AFL) or
genlock (default).
Enable input AFL
E 1 GLOK } Glok 1 ]
Lock the output refresh rate to
the rate of the selected input.
Enable SDI genlock
(DSC HD-3G A only)
E 2 GLOK } Glok 2 ]
Lock the output refresh rate to
the applied genlock signal.
View the genlock or AFL
setting
E GLOK } X6$ ]
In verbose modes 2 and 3:
Glok X6$ ]
View the current global input
lock (AFL) or genlock setting.
View genlock or AFL
status
E 41 STAT X6% ]
In verbose modes 2 and 3:
41 Stat X6% ]
View the current global input
lock (AFL) or genlock status.
Genlock Offset (DSC HD-3G A only)
Set horizontal offset
E H x GLOF } Glof H x ]
Set the horizontal genlock offset
to x pixels. The x value (genlock
pixel offset) range is ± the
current output resolution total
pixel value -1.
Example: -2199+2199 for
1080p
View horizontal offset
E H GLOF } x ]
In verbose modes 2 and 3:
Glof H x ]
View the horizontal genlock
offset (default = 0).
Set vertical offset
E V y GLOF } Glof V y ]
Set the vertical genlock offset
to y pixels. The y value (genlock
pixel offset) range is ± the
current output resolution total
pixel value -1.
Example: -1124+1124 for
1080p
View vertical offset
E V GLOF } n ]
In verbose modes 2 and 3:
Glof V y ]
View the vertical genlock offset
(default = 0).
NOTES:
Genlock offset commands return an error code unless SDI genlock is currently enabled and genlock is
currently locked to an applied genlock reference.
Genlock offsets apply only to the current output resolution and reset to 0,0 when the output resolution is
adjusted.
NOTE: X4$ = HDCP status: 0 = no sink device detected, 2 = sink detected
X6$ = Input lock (AFL) status:
0 = Input lock disabled (default)
1 = Input lock is enabled but cannot lock to applied input signal (defaults to the set output rate).
2 = Input lock is enabled. The output is locked to the applied input signal (AFL).
X6% = SDI genlock status:
0 = Disable (default), 1 = Priority to highest numbered input, 2 = Priority to lowest numbered input
DSC 3G-HD A and DSC HD-3G A • Remote Configuration and Control 56