Hitachi 42HDT50 Flat Panel Television User Manual


 
RGB ON SCREEN DISPLAY
67
USING THE RGB INPUT
4. Other signal formats may not be displayed correctly. Use AUTO ADJUST to automatically adjust the horizontal position, vertical posi-
tion, clock, and phase. We recommend you use a signal, which has more than 50% of amplitude of white area at each corner of
the picture, when performing Auto Adjustment. It may not work correctly with dark picture (see page 72).
5. Input signal level.
6. RGB input signal will not appear at all when receiving a signal which is not supported by this product. If the setting is wrong, the
Display Monitor will display:
SYNC TTL level H/V separate signal
RGB INPUT 0.7Vpp/1.0Vpp
NO SYNC. SIGNAL
INVALID SCAN FREQ.
Without sync Either horizontal or vertical
frequency is inappropriate
or out of range.
POWER SAVING mode will come
on after 10 seconds.
INVALID SCAN FREQ. will disappear
after 60 seconds.
NOTE: 1. If the Display Monitor cannot display a signal, please try AUTO ADJUST to display the signal. This is used to initialize
the MultiScan Converter.
2. Not all signals have AUTO ADJUST feature (see page 72).
3. Set-Top-Box and DVD player input signal does not have AUTO ADJUST feature.
NOTE: Interlaced signal is not available.