Honeywell HXCT16 Home Theater Server User Manual


 
Manual Alarm Action Setup (2)
< Figure 22 > Manual Alarm Action Setup (2) screen.
This screen allows you to set the actions the operator can take, what
relays will be activated and what cameras are associated with other
cameras.
There are three possible settings. Timed: The alarm will
“time out” at the designated time (Hold Time) unless the operator
clears it earlier.
Latched : The alarm remains active until the operator acknowledges
it. Trans (Transparent): The alarms are not latched and cannot be
cleared by the operator.
There are four possible relay settings. 1 or 2: Sets either
internal relay 1 or 2 to be activated by an alarm. 1&2: Sets both
internal relays 1 and 2 to be activated by an alarm. Off: Neither
internal relay will be activated by an alarm.
Action :
Relay :
Alarm Link : This selects whether the alarm action will be linked or
not. It can be set to Off or any of the 16 alarm actions. All alarm
actions take priority over manual alarm actions.
29
ENGLISH