34
EN
CORRECTIVE ACTION
Set the clock and/or timer correctly.
Press TIMER and check to make sure
that ‰ appears on the front display
panel.
Re-perform the set-up procedures.
Timer programing cannot be performed
when timer recording is in progress.
Wait until it finishes.
Load a cassette with the record safety
tab intact, or with the hole covered
with adhesive tape.
Remove the cassette and cover its
hole with adhesive tape, or replace it
with a cassette on which the safety
tab is intact.
Check the programed data and set
again if necessary, then press TIMER
again.
The program may not have been
recorded in its entirety. Next time be
sure you have enough time on the
tape to record the entire broadcast.
Wait until a space in memory clears,
or cancel unnecessary program
information (੬ pg. 26).
SYMPTOM
1. Timer recording will not work.
2. Timer programing will not work.
3. ‰ and ] on the front display
panel will not stop blinking.
4. The cassette is automatically
ejected, and ‰ and ] on the
front display panel will not stop
blinking.
5. ‰ blinks for 10 seconds and the
timer mode is disengaged.
6. The cassette is automatically
ejected, the power shuts off and ‰
and ] will not stop blinking.
7. “PROGRAM FULL” is displayed on
the screen.
POSSIBLE CAUSE
● The clock and/or the timer have
been set incorrectly.
● The timer is not engaged.
● The VCR has not been set up properly.
● Timer recording is in progress.
● The timer is engaged but there is no
cassette loaded.
● The loaded cassette has had its
record safety tab removed.
● TIMER has been pressed when there
are no programs in memory, or the
timer recording program has not
been set correctly.
● The tape reaches its end during
timer recording.
● All 8 programs of the VCR’s timer
memory are used.
TIMER RECORDING
OTHER PROBLEMS
CORRECTIVE ACTION
If you need the skipped channels,
restore them (੬ pg. 14).
Press PAUSE ( 8 ) to pause the
recording, change channels, then
press PLAY ( 3 ) to resume recording.
Select a different host channel during
Semiauto Clock Set (੬ pg. 11), or
perform Manual Clock Set (੬ pg. 12).
SYMPTOM
1. When scanning channels, some of
them are skipped over.
2. The channel cannot be changed.
3. Even though Auto or Semiauto
Clock Set has been performed, the
clock is incorrect.
POSSIBLE CAUSE
● Those channels have been preset to
be skipped.
● Recording is in progress.
● The clock setting data received from
the host channel is incorrect.
TROUBLESHOOTING (cont.)