![](http://pdfasset.owneriq.net/d/dc/ddcbeb65-2c13-42a0-88c8-73f12e4614db/ddcbeb65-2c13-42a0-88c8-73f12e4614db-bg73.png)
5.16 Replacing the Skew Belt
(European Systems Only)
1. Using a
7
⁄16" wrench, carefully disconnect the RF
cables from the LNB.
2. Disconnect the elevation gyro cable from the
in-line connector.
Maintenance
54-0198
117
Figure 5-38
European LNB/Feed Tube
Assembly
Figure 5-39
Elevation Gyro Cable
RF Cable
Connectors
LNB
Skew
Motor
Elevation
Gyro
Gyro Cable
Connector