LG Electronics 22LG3DDH CRT Television User Manual


 
21
206-4096
012 - IR BANKS EN (IR Banks Enable)
For direct access to a particular channel bank. When enabled, you
can access a channel bank by inputting the IR code for the bank.
013 - SCAN MODE (Functional after 2-5-5 + MENU setup
transfer)
Allows variation in turning the TV On/Off with Channel Up/Down.
You may opt for TV channels only or TV channels + Off/On. If set
to 0, Channel Up/Down keys change channels only. If set to 1,
channel DOWN below the lowest channel or Channel UP above
the highest channel to turn the TV Off.
014 - STRT CH IN SM (Start Channel in Scan Mode)
If set to 1, installs TV On/Off event below the start channel at
TV turn On. If set to 1, the user can select channels with either
Channel Up/Down or by direct keypad entry. If set to 0, only those
channels that are entered for scanning can be selected.
015 - SLEEP TIMER
If set to 1, the Sleep Timer feature may be used. If set to 0, the
Sleep Timer is not available.
016 - EN TIMER (Enable On/Off Timers) *
If set to 1, the Timer function is available to the end user and
enabled continuously. Set to 0 to disable On/Off Timers.
Note: Clock must be set in order to use timers.
017 - ALARM *
Gives the installer the option of making the Alarm function avail-
able to the end user. If set to 1, the Alarm function is available to
the end user. Set to 0 to disable the Alarm function.
Note: Clock must be set before the Alarm function will work.
020 - FEATURE LEVEL
Leave item 20 FEATURE LEVEL set to 1 (default). Default set
to ZEN 1 for Zenith IR codes remote control operation. Set O, P
LBL for Zenith Private Label IR remote control operation.
Warning: Do not set to “0” or remote will not control TV.
021 - V-CHIP (Parental Control) *
Set to 1 to activate V-Chip (Parental Control) and have it available
to the end user to lter and control or otherwise restrict program-
ming content that can appear. Set to 0 to turn the V-Chip feature
Off (not available to user); no programming restrictions can be set.
022 - MAX BLK HRS (Maximum Block Hours) *
Sets hours from 0 to 99 for the maximum V-Chip (Parental Con-
trol) block hours. Default setting is for 12 blocking hours.
023 - CAPTION LOCK
If set to 0, captions are OFF when the TV is turned ON. Set to 1
to use the caption setting con gured before the TV was turned Off
when the TV is turned ON.
* Only affects Function Menu if enabled by some PPV providers.
025 - FUNCTION PRE (Function Preview)
Set to 0 to suppress CHANNEL PREVIEW from the Function
Menu with some Pay-Per-View systems.
027 - HOSPITAL MODE
With this setting two things are affected: Channel Banks 1, 2, and
3 are accessible, while Channel Bank 4 can be made inactive by
removing all the channels from Channel Bank 4. Then, if Channel
Bank 4 is selected when the TV is turned On, the TV screen will
show “Inactive TV.” The Channel Bank 4 setup allows the hospital
to present TV viewing options to the patient. The patient can select
programming options available in Channel Banks 1, 2, or 3. Chan-
nel Banks are available in all Hospital Modes (1, 2, etc.).
The IR code that will control the TV depends on the Installer Menu
item 020 FEATURE LEVEL setting.
For LG3DCH TVs
It is recommended that you leave this item set to 2 (default), which
favors most hospitals.
Hosp. Mode = 0 Hospital Mode disabled.
Hosp. Mode = 1 Zenith Private Label IR Code (Bed 1)
Hosp. Mode = 2 Zenith Consumer IR Code (Bed 2)
For LG3DDH TVs
Set according to the pillow speaker supply voltage and audio
source (see table below). Note the following regarding pillow speak-
er voltage: +12 v identi es a Zenith pillow speaker, +5 v identi es a
Phillips pillow speaker, and -5 v identi es an RCA pillow speaker.
Note: The default setting (254) is not selectable in the Installer
Menu. If you ever need to restore the default setting, you must set
item 117 FACT DEFAULT to 1 to reload the factory default settings.
See item 117 description for further information.
Item 27
Value
Hospital Mode
Pillow
Speaker
Voltage
Audio Source
(Switch = Pil-
low)
000 Disabled +12 v Pillow Only
001 Enabled, Zenith Private Label +12 v Pillow Only
002 Enabled, Zenith Consumer +12 v Pillow Only
017 Enabled, Zenith Private Label +5 v Pillow Only
018 Enabled, Zenith Consumer +5 v Pillow Only
033 Enabled, Zenith Private Label -5 v Pillow Only
034 Enabled, Zenith Consumer -5 v Pillow Only
065 Enabled, Zenith Private Label +12 v Main Only
066 Enabled, Zenith Consumer +12 v Main Only
081 Enabled, Zenith Private Label +5 v Main Only
082 Enabled, Zenith Consumer +5 v Main Only
097 Enabled, Zenith Private Label -5 v Main Only
098 Enabled, Zenith Consumer -5 v Main Only
129 Enabled, Zenith Private Label +12 v Pillow & Main
130 Enabled, Zenith Consumer +12 v Pillow & Main
145 Enabled, Zenith Private Label +5 v Pillow & Main
146 Enabled, Zenith Consumer +5 v Pillow & Main
161 Enabled, Zenith Private Label -5 v Pillow & Main
162 Enabled, Zenith Consumer -5 v Pillow & Main
254 Enabled, Zenith Consumer 0 v Main Only
Installer Menu (Cont.)