Magma MDR 24/96 DVD Recorder User Manual


 
22
MDR 24/96
MDR 24/96
Note:Note:
Note:Note:
Note: Determining
which unit in
Figures
2 & 3
provides master
clock depends on
your application. For
information on ad-
vanced applications,
see the Technical
Reference manual.
ADAT Optical Hookup (DIO•8 or OPT•8)
Cables & Hardware
(3) DIO8 or OPT8 cards for MDR24/96
(3) DIO
8 or OPT8 cards for D8B
(1) Clock I/O card for D8B
(6) ADAT Optical cables
(1) 75 BNC word clock cable
Hookup
1. Connect three ADAT Optical cables from the MDR24/96 Optical Outputs to
the Optical Inputs on the corresponding D8B I/O cards.
2. Connect three ADAT Optical cables from the MDR24/96 Optical Inputs to
the Optical Outputs on the corresponding D8B I/O cards.
3. When ADAT Optical is used, the D8B must have a Clock I/O card
installed. To make the D8B the clock master, connect its Word Clock Out
to the MDR24/96 Word Clock In. To make the MDR24/96 the clock
master, connect its Word Clock Out to the D8B Word Clock In.
MDR24/96 Settings
1. If you have DIO•8 cards installed, set the Tape Input and Tape Output
format for each card to ADAT. OPT•8 cards need no configuration.
2. If the MDR24/96 is the clock master, set the Sample Clock to Internal; If
the MDR24/96 is a clock slave, set the Sample Clock to Word Clock and
depress the 75 termination button on the Sync card.
3. Set the Sample Rate to 44.1 kHz or 48 kHz according to your preference.
Console Settings
1. If you have DIO8 cards installed, set the Tape Input and Tape Output
format for each card to ADAT. OPT
8 cards need no configuration.
2. If the D8B is the clock master, set the Sample Clock to either 44.1 k
Internal or 48 k Internal; if it is a clock slave, then set the Sample Clock
to either 44.1 kHz or 48 kHz. Set the Sample Rate to match the Sample
Rate selected on the MDR24/96.