Mitsubishi Electronics OD62D TV Mount User Manual


 
8 - 15 8 - 15
MELSEC-Q
8 PROGRAMMING
(3) Operating GX Configurator-CT
(a) Initial settings (see Section 7.4)
Set the values on the window as shown below.
Setting item Description Setting
Preset value setting Set the preset value. 2500
Coincidence output point set No. 1 Set the value for coincidence output point No. 1. 1000
Coincidence output point set No. 2 This is not used.
Counter function selection setting
Set the counter function to be used.
When a counter function is not used, sets any function.
Set according to the
function used.
Set "1000" when the sampling counter function is used. 1000 Sampling/periodic setting
[Unit: 10 ms]
Set "500" when the periodic pulse counter function is used. 500
Ring counter minimum value Set only when the ring counter function is used. -5000
Ring counter maximum value Set only when the ring counter function is used. 5000