Data Transfer
Service Data is duplicated and stored in separate EEPROMs in two locations.
PWB-MAIN - Working data for TV operation
OPTICAL ENGINE - Backup data
The Optical Engine also includes data for the Color Wheel Index Delay setting determined at the factory.
Procedure:
1. Enter the Service Mode <MENU><2-4-5-7> Select the Data Transfer & Geometry Menu <0>
Note: Besides MANUAL GEOMETRY ALIGNMENT, four data transfer choices are listed on screen.
RESTORE ENGINE DATA FROM BACKUP - copies backup factory adjustments HVPOS, White
Balanceand Index Delay from the Optical Engine to the PWB-MAIN.
RESTORE GEOMETRY DATA FROM BACKUP - copies backup factory Geometry Alignment data from
the Optical Engine to the PWB-MAIN.
RESTORE INDEX DELAY - copies factory Index Delay Adjustment data from the Optical Engine to the
PWB-MAIN.
SAVE ENGINE AND GEOMETRY SETTING TO BACKUP - copies all working data from the PWB-
MAIN into backup memory on the Optical Engine.
2. Use the <TS> buttons to select the data transfer item and press <ENTER>.
3. Press <BACK> to quit.
After Engine Replacement:
1. Restore Index Delay.
2. Save Engine and Geometry Setting to Backup
After PWB-MAIN Replacement:
1. Restore Engine Data From Backup
2. Restore Geometry Data From Backup.
Data Transfer & Geometry Menu
<MENU><2-4-5-7><0>
RESTORE ENGINE DATA FROM BACKUP
RESTORE GEOMETRY DATA FROM BACKUP
MANUAL GEOMETRY ALIGNMENT
RESTORE INDEX DELAY
SAVE ENGINE AND GEOMETRY SETTING TO BACKUP
Warning
- Only use "SAVE ENGINE AND GEOMETRY SETTING TO BACKUP"
after Optical Engine replacement.