Niles Audio RCA-TT Universal Remote User Manual


 
14
REMOTE CONTROL ANYWHERE! KIT
CONNECTION HUB
Figure 13: Connecting the
Status Adapter
Optional Niles Universal
12VDC Power Supply
(FG01035)
INSTALLATION (CONTINUED)
RUNNING SENSOR CABLE IN NEW CONSTRUCTION
Scheduling and Preparation
Plan to schedule the sensor wiring after the electrical wiring is finished. That way you can avoid cable
routes which could potentially induce interference over the sensor cable. The basic rules are:
• Never run the sensor cable through the same hole as an electrical cable.
• Never run the sensor cable into the same J-box as electrical cable.
• Avoid running the sensor cable beside the electrical cable. Keep it at least 3 or 4 feet distant
from any electrical power cable.