Warning messages
Error messages
Priority
OMonitor display
ODescription
OVTR operation and corrective action
High E-04 (UNKNOWN SIG)
This appears when the SDTI input signals are not
DVCPRO or DV format signals. (The data stream
format complies with the SMPTE 321M standard.)
VTR: No recording operations can be performed.
OCheck whether the SDTI input has been
connected properly.
(This warning is displayed when SDI signals are
being input.)
Priority
OMonitor display
ODescription
OVTR operation and corrective action
Low
E-01 (LOW RF)
This appears when envelope levels approximately
1/3 that of normal levels are detected for more than
one second during playback, recording, or editing.
VTR: Operation continues.
OClean the video heads.
E-02 (HIGH ERROR RATE)
This appears when the error rate has increased to
the extent that correction or interpolation was
performed on either the video or audio signals.
VTR: Operation continues.
OClean the video heads.
E-11 (NOT 1a25M SIG)
This appears when the SDTI input signals are not
DVCPRO (25 Mbps) format 1a transfer signals.
VTR: No recording operations can be performed.
OCheck the SDTI input signals.
E-12 (NOT 1a50M SIG)
This appears when the SDTI input signals are not
DVCPRO50 (50 Mbps) format 1a transfer signals.
VTR: No recording operations can be performed.
OCheck the SDTI input signals.
E-00 (SERVO NOT LOCKED)
This appears when the servo is not locked for three
or more seconds during playback, recording, or
editing.
VTR: Operation continues.
OCheck the tape.
A tape recorded other than NTSC format may
have been inserted.
E-16 (INVALID VIDEO SIG)
This appears when the compressed video signals in
the SDTI input signals are invalid.
OThis warning appears only during recording
operations. In cases like this, no signals are
recorded on the tape and only the erasure of the
existing signals will be performed.
VTR: Operation continues.
No editing operations can be performed.
OCheck the SDTI input signals.
Playback signals of tape on which material has
not been recorded may be being input.
E-17 (INVALID AUDIO SIG)
This appears when the audio signals in the SDTI
input signals are invalid.
OThis warning appears only during recording
operations. In cases like this, the signals are
recorded with the audio signals muted.
VTR: Operation continues.
No editing operations can be performed.
OCheck the SDTI input signals.
Signals from other than a VTR with 1a playback
may be being input.
E-18 (INVALID TC SIG)
This appears when the time codes in the SDTI input
signals are invalid.
OThis warning appears only during recording
operations. In cases like this, the internally
generated time codes are recorded.
VTR: Operation continues.
No editing operations can be performed.
OCheck the time code being input from the
components.
E-10 (FAN STOP)
This is displayed when the fan motor stops.
VTR: Operation continues.
OCheck that nothing is obstructing the fan
movement.
E-09 (NO RF)
This appears during playback when a blank section
(tape blank) lasting for one or more seconds has
been detected.
Such a section is identified as a tape blank when all
of the following conditions are met.
ONo head outputs
ONo playback data readout
ONo CTL (Excluding DV and DVCAM tapes)
VTR: Operation continues.
OCheck the tape.
A tape on which material has not been recorded
may have been inserted.