When VAS (Voice Activated System) is set, if silence continues for approx. 2 seconds during
microphone recording, the recording is paused automatically. If the unit detects sound, the recording
resumes.
* When the recording level adjustment is MANUAL ( page 27), even if the VAS setting is set to ON, the setting
does not change to the VAS recording.
* For important recording, set the VAS setting to OFF.
* If the “LOW CUT FILTER” setting is “ON”, low frequency sound may be cut out and VAS recording may not activate.
In this case
, change the “LOW CUT FILTER” setting to “OFF”. (page 26)
* If the recording is paused with no sound state, “
” blinks. When [REC *] is pressed from this recording pause
state, the status is changed to normal recording pause state and “
” lights up.
Preventing unnecessary recording (VAS)
Set the recording level adjustment to AUTO
beforehand. ( page 27)
Press [STOP g/RETURN] to stop the unit.
1
Press [MENU].
2
Press +, – to select “
MIC REC MENU
and press
[q OK]
to enter.
3
Press +, – to select “VAS” and press
[q OK]
to enter.
4
Press +, – to select “ON” and press [q OK]
to enter.
(The factory setting is “OFF”.)
To exit the setting screen, press [F2 (CLOSE)].
” is displayed.
To start VAS recording, press [REC *].
Adjusting the VAS operation level:
Press u, i during VAS
recording.
(The factory setting is “3”.)
*
You can adjust the sound detection level from 1 to 5.
* If the audio to record is low, increase the VAS value
(sensitivity level). If the sound is loud, decrease the
VAS value.