FILTER PUMP DOES NOT OPERATE
:
1.
At the CP-2000, check that FILTER Status Light is ON
2. At the LX-10, turn SYSTEM CONTROL Switch to the "SERVICE" position, and FILTER
Switch at MANUAL CONTROL to the "ON' position.
3.
If filter pump operates, there is a possible malfunction at the LX-10 circuit board.
4.
If filter pump does not operate. pump may require servicing.
POOL CLEANER DOES NOT OPERATE
:
1.
At the CP-2000, check that CLNR is switched ON, and that four minute "pool cleaner on
delay" has expired.
2. At the LX-10, turn SYSTEM CONTROL Switch to the "SERVICE" position, and CLNR
Switch at MANUAL CONTROL to the "ON"
pos~tion.
3.
If pool cleaner pump operates, there is a possible nlalfunction at the LX-10 circuit board
4.
If pool cleaner does not operate, pump may require servicing.
5.
If system incorporates a pool cleaner valve, check that cable has not been unplugged
from Valve Operator.
HEATER DOES NOT OPERATE
:
1.
At the CP-2000, make sure that POOLand SPA Heat Select Switches are in the
"HEATER" or
"S. PREF" position, and that THERMOSTAT Dials are set correctly.
2. Check the WATER TEMPERATURE Display. Three dashes or an unreasonably high
temperature indicates that there is a malfunction at the Water Sensor.
3.
Check that filter pump is running.
4.
Check the filter pressure. If filter is clogged. the heater may not be getting sufficient
water flow.
5.
Inside the heater, check pilot light and heater controls. Heater must be turned on, and
its own thermostat must be turned all the way up.
6.
Heater may require servicing.
SOUR DOES NOT OPERATE
:
Note: Ambient air temperature must be approximately
5
degrees warmer than the water
temperature before the solar system is activated.
1.
Check that filter pump is running.
2. At the CP-2000, make sure that POOLand SPA Heat Select Switches are in the
"SOLAR" or
"S.PREF position, and that THERMOSTAT Dials are set correctly.
3.
Check that cable has not been unplugged from Solar Valve Operator.
4.
At the W-10, turn SOLAR CONTROL Switch to the "ON posit~on, and check to see if
Solar Valve rotates. Return Switch to "AUTO" position at completion of test.
SPA DOES NOT HEAT UP TO
104"
F
:
1.
Inside the heater, check that thermostat is turned all the way up.
2. High limit control on heater may need adjusting. Refer to a qualified Service Company.
3.
If HEATER Status Light at the CP-2000 turns off before spa attains the maximum
temperature of 104" F, the Controller may need a calibration adjustment.
SPA DRAINS OR OVERFLOWS
:
1.
At the W-10, check that FLOW CONTROL Switch is not in "FILL" or "DRAIN" position.
2.
Check that cables have not been unplugged from Valve Operators.
SPA WATER LEVEL DROPS SLOWLY
:
1.
Valves may need servicing.
CONTROLLER
Installed in a convenient location inside your house, the CP-2000 CONTROLLER gives you
fingertip control of all the equipment associated with your swimming pool and spa.
TIME CONTROL
'(;
CP-2000
2)
rllrER
CLVR
$PA
AUXI
i
--
TIME CONTROL
:
The Controller houses an electronic time clock for programming the daily operating
cycles of your pool equipment.
There are four Equipment Buttons which are used for turning the equipment ON and OFF:
FILTER Button: Activates filter pump and circulates water for pool filtration.
Enables pool to be heated.
CLNR Button: Activates pool cleaner (after
4
minute delay), and also filter pump if
FILTER Button is not already switched ON.
SPA Button:
Activates filter pump and rotates valves to spa circulation. Enables spa to
be heated. Disables the CLNR Button and turns pool cleaner OFF.
AUX
1
Button: Activates auxiliary equipment (such as spa light).
The PROGRAM, HOURS and MINUTES Buttons are used for setting the Clock and for
programming the daily operation of the pool equipment.
(See Page
8).
The DELAY CANCEL Won is used to override the "Filter Pump Off Delay" or "Pool
Cleaner On Delay" circuits (for testing and servicing purposes only).
REMOTE CONTROL
:
Additional remote circuits may have been added to your system to control more auxiliary
equipment (such as a pool light, air blower, jet pump, waterfall, etc.)
Note: These functions are not
wntrolled by the Programmable
Clock.
STATUS DISPLAY
:
Status Lights are provided for the various pieces of equipment controlled by the CP-2000.
The presence of a light indicates that the equipment has been activated. The absence of
a light indicates that the equipment is turned off.