Pentair CP-2000 Universal Remote User Manual


 
"PROG
3
will now appear on the r~ght of the Display. This indicates that the third
program step is ready to be entered.
Enter the third program time
(12:OO pm) by
pushing the HOURS and MINUTES Buttons
Pay special attention to the
AM/PM indicator.
In our example, at
12:OO pm the filter pump
and pool cleaner should turn off.
Make sure that "OFF' is displayed above each
Equipment Button.
You have now completed the third program step
Push PROGRAM Button to lock-in the program.
r
9
TlME CONTROL
FILTER CLMR SPA AUXI
MINUTES
+
I
"PROG
4
will now appear on the right of the Display. This indicates that the fourth
program step is ready to be entered.
Enter the fourth program time
(6:30 pm) by
pushing the HOURS and MINUTES Buttons.
In our example, at
6:30 pm the spa and
auxiliary 1 (spa light) should turn on.
Push SPA Equipment Button.
"ON should appear directly above the SPA
and FILTER Buttons.
Push AUXl Equipment Button.
"ON' should appear above AUXl Button
You have now completed the fourth program
step.
Push PROGRAM Button to lock-in the program.
#
4
TlME CONTROL
RUIR CUR SPA AUXt
I
"PROG 5" will now appear on the right of the Display. This indicates that the fifth
program step is ready to be entered.
Enter the fifth program time
(8:OO pm) by
pushing the HOURS and MINUTES Buttons.
In our example, we would like to turn off the
spa at
8:00 pm, but the spa light (AUX 1)
should still be on.
Push AUX 1 Equipment Button.
"ON" will appear above
AUXl Button.
You have now completed the fifth program step.
Push PROGRAM Button to lock in the program
#
9
TlME CONTROL
CfF OFF OFF
---•
RLTSR CLWR SPA AUXI
.
I
"PROG
6
will now appear on the right of the Display. This indicates that the sixth
program step is ready to be entered.
Enter the sixth program time
(10:OO pm) by
pushing the HOURS and MINUTES Buttons.
In our example, all of the equipment should be
turned off at
10:OO pm.
Therefore, make sure that "OFF' is displayed
above all of the Equipment Buttons.
To lock-in the program and return Clock to
Time Mode, simply push the PROGRAM
Button once.
If
this is forgotten, the
Clock
will automatically
return to Time Mode after two minutes.
.
9
TIME CONTROL
RUII
CU
SPA AUX1
\
I
SYSTEM OPTIONS
TWO SPEED PUMP CONTROL
:
If your system incorporates a Two Speed Filter Pump, the CP-2000 has been designed to
provide you with the maximum energy-efficient usage of this feature.
Although your Pool Builder may have adjusted the two speed control circuitry to your
specific requirements, the CP-2000 typically switches the pump to high speed under any
of the following conditions:
1. For two minutes when the filter is first turned on. This features establishes proper flow
through the system, and packs the filter grids. After two minutes, the pump will
automatically switch to low speed.
2. Whenever the pool cleaner is running. This provides sufficient flow for the pool
cleaner to operate effectively.
3. During spa operation to increase
the jet action.
4.
Whenever the heater is on. This feature will conserve energy by bringing your pool
and spa up to the desired temperature more quickly.
5. Whenever your solar system is operating. This provides high flow rate through your
solar panels, which ensures the most efficient usage of the available solar energy.
SPA WATERFALL CONTROL
:
If your spa water level is elevated above that of the pool, your Pool Builder may have
included a Spa Waterfall Control (model
RLY-WRFL).
With this feature, you can circulate the pool water back to the spa, creating an overflow
(waterfall effect) from the spa to the pool. This effect will cease during spa circulation.
Depending upon which circuit has been used to connect the Spa Waterfall Control, either
the
AUX1. AUX2 or AUX3 Button will activate this feature.
FREEZE PROTECTION
:
Recirculating Freeze Sensors (model FPSC) may have been added to your system.
These Sensors protect the plumbing and equipment from possible freeze damage by
running the filter pump whenever the temperature falls to approximately 41" F.
Similarly, Auxiliary Pump Freeze Sensors (model
FPSAUX) may have been added to
activate auxiliary equipment (such as a fountain or jet pump) during freezing conditions.
CAUTION
:
Freeze Sensors will not provide circulation of water through your solar panels.
Solar freeze protection must be accomplished by draining the panels. (See below).
SOLAR PANEL DRAINDOWN
:
If your control system incorporates solar heating, it is advisable that a draindown feature
be included to protect the solar panels against potential freeze damage.
For conventional solar systems which permit gravity drainage of panels, the Compool
Solar Valve with built-in check valve (model
SOL-2T) will automatically drain the panels
whenever the solar turns off and the filter pump is not running.
For solar systems with glazed panels. damage can occur from overheating if the solar
turns off and the filter pumw is still running.
In this instance, a motorized Draindown Valve (model
HW-5B) should be plumbed at the
solar feed line. This will automatically drain the panels whenever the solar is turned off,
even if the filter pump is still running.
This feature may also be incorporated if your solar system does not facilitate gravity
drainage of panels, or where panels are located below pool water level.
Consult your Solar Company for more details.