Philips 42-3D6W02/00 Flat Panel Television User Manual


 
Display User Manual
3D Solutions
23 September 2008
20 of 26 ©2008 Philips Electronics Nederland B.V.
7 Interfaces
7.1 DVI-in
Pin Signal Pi
n
Signal Pi
n
Signal
1 T.M.D.S.
Data2-
9 T.M.D.S.
Data1-
17 T.M.D.S.
Data0-
2 T.M.D.S.
Data2+
10 T.M.D.S.
Data1+
18 T.M.D.S.
Data0+
3 T.M.D.S.
Data2/4
Shield
11 T.M.D.S.
Data1/3
Shield
19
T.M . D. S .Da t
a0/5 Shield
4 No
connect
12 No
connect
20
No connect
5 No
connect
13 No
connect
21
No connect
6 DDC
Clock
14 +5V
Power
22 T.M.D.S.
Clock Shield
7 DDC Data 15 Ground
(for +5V)
23
T.M.D.S.
Clock+
8 No
connect
16 Hot Plug
Detect
24 T.M.D.S.
Clock-
The DDC Clock and the DDC data are used by the Display Control Tool to control depth and colour
settings in the display.
7.2 LED
LED Color Status
Red Display is in standby mode. No DVI clock is present.
Green Display on