Philips BDL4771V Flat Panel Television User Manual


 
User Manual BDL4771V
RETURN TO THE CONTENTS
Note: PIP function is disabled when Tiling is enabled.
Switch on delay: Choose to enable or disable a sequence in turning on the screen matrix. If enabled, the
display will turn on one horizontal matrix at a time starting from the top row.
Heat status
This function allows you to check the thermal status of the display at any time. The accuracy of the
temperature indicated is 5 degrees Celsius.
Press the PLUS button to view the heat status. Press the EXIT button to return to the previous menu.
Date and time
Adjusts current date and time for the display’s internal clock.
Press the UP/DOWN button to toggle between the Ye ar, Month, Day, Hour, Minute, and Daylight
saving time settings, and then press the PLUS/MINUS button to adjust.
Schedule
Note: Please set up current date and time in Date and time before using the Schedule function.
This function allows you to program up to seven different scheduled time intervals for the display. You can
select the time the unit turns on and turns off, the days in a week it is activated, and which input source the
display will use for each scheduled activation period.
For example, if you wish to turn the display on automatically at 7:30 AM and off at 10:30 PM on Tuesdays and
Wednesdays and display the signal from the HDMI input:
Perform the following steps:
1. With the Schedule item highlighted in the Advanced option menu, press the PLUS button to open
the submenu.
2. Press the UP/DOWN button to select schedule item #1 ( 1), then press SET. A check mark will
appear in the box indicating that the schedule item has been selected.
3. With the On item highlighted, press the SET button and then press the UP/DOWN button to set the
power on hour to “07”.
4. Press the PLUS button to move to the minute slot. Press the UP/DOWN button to set the power on
minute to “30”, then press the EXIT button.
5. Press the PLUS button to highlight the Off item. Press the SET button, and then press the UP/DOWN
button to set the power off hour to “22”.
Time
0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:00
Day
MON Off
TUE Off On Off
WED Off On Off
THU Off
FRI Off
SAT Off
SUN Off
_
+